Rawax

Cut and Fill Calculation: Average End Area vs Prismoidal vs TIN Methods (Worked Example)

Rawax Engineering Team · Updated

Open the Rawax platform →

Cut and fill volumes are calculated by comparing an existing ground surface with a design surface. The three standard methods are the average end area method (V = L × (A₁ + A₂) / 2), the prismoidal formula (V = L × (A₁ + 4Aₘ + A₂) / 6) and the TIN-to-TIN (composite) method, which subtracts two triangulated surfaces directly. For linear works such as roads, end-area methods on cross-sections are standard; for sites and platforms, surface-to-surface methods are more accurate.

The three methods at a glance

Method Formula Best for Typical accuracy
Average end area V = L (A₁ + A₂) / 2 Roads, channels, cross-section based quantities Slightly overestimates when areas change quickly
Prismoidal V = L (A₁ + 4Aₘ + A₂) / 6 Same as above, when higher accuracy is needed Exact for prismoids
TIN-to-TIN (composite) Sum of prism volumes between two triangulated surfaces Building platforms, sites, before/after surveys Depends on survey density
Grid method Sum of cell area × average depth difference Quick checks, independent verification Depends on grid size

Method 1: Average end area

Compute the cut (or fill) area at each cross-section, then multiply the average of two consecutive areas by the distance between them:

V = L × (A₁ + A₂) / 2

where A₁ and A₂ are the areas of two consecutive sections (m²) and L is the distance between them (m). It is simple and is the method most road contracts and payment measurements use.

Method 2: Prismoidal formula

The prismoidal formula adds the area of a section halfway between the two end sections:

V = L × (A₁ + 4Aₘ + A₂) / 6

Important: Aₘ is not the average of A₁ and A₂. It is the area of the middle section computed from the averaged dimensions (depth, widths) of the end sections. If you use the averaged area, the formula collapses back to the average end area result.

Worked example

A road cutting has a 10 m base width and 1:1 side slopes. The trapezoidal cut area for depth d is A = (b + s·d)·d, with b = 10 m and s = 1.

Section Chainage Depth d (m) Area (m²)
Start 0+000 1.0 (10 + 1.0) × 1.0 = 11.00
Middle 0+010 1.5 (10 + 1.5) × 1.5 = 17.25
End 0+020 2.0 (10 + 2.0) × 2.0 = 24.00

Average end area: V = 20 × (11 + 24) / 2 = 350.00 m³

Prismoidal: V = 20 × (11 + 4 × 17.25 + 24) / 6 = 20 × 104 / 6 = 346.67 m³

The difference is 3.33 m³ (about 1%). It equals the prismoidal correction for this section shape, C = L · s · (d₁ − d₂)² / 6 = 20 × 1 × 1² / 6 = 3.33 m³. Over a long road with frequent depth changes, this difference adds up, which is why specifications often state which method governs payment.

Method 3: TIN-to-TIN (composite) volumes

For sites and platforms, build a triangulated irregular network (TIN) from each survey (existing and design, or before and after). The volume between the two surfaces is the sum of the prism volumes under each triangle. A careful implementation splits every triangle along the line where the elevation difference is zero (Δz = 0), so cut and fill are separated exactly rather than averaged.

An independent grid method is a good check: if the TIN and grid results differ by more than a small percentage, look for survey gaps, wrong boundaries or swapped coordinates.

Common errors that break earthwork quantities

How Rawax calculates cut and fill

Rawax builds the TIN with Delaunay triangulation, checks the data (unreadable rows, duplicate point numbers, same-location points with different elevations, outliers), then computes volumes with two independent methods: composite TIN-to-TIN with exact Δz = 0 splitting, and a grid method for verification, showing the percentage difference between them. For roads, it computes cross-sections at any interval and volumes by both average end area and prismoidal methods, with a mass haul diagram.

Every result comes with a calculation sheet: inputs, formula, steps, results and warnings. The engine is checked by automated tests against analytical answers, for example a tilted plane against a level (12,500 m³ cut and 12,500 m³ fill), a pyramid (V = A·h/3) and a paraboloid pit (π·R²·h/2).

You can try the free public cut and fill calculator on rawax.io without signing up. Results export to Excel, DXF (3DFACE surfaces with CUT and FILL layers) and a printable report.

FAQ

What is the formula for cut and fill?

For cross-sections, the average end area formula is V = L × (A₁ + A₂) / 2 and the prismoidal formula is V = L × (A₁ + 4Aₘ + A₂) / 6. For surfaces, the volume is the sum of prism volumes between the existing and design TINs.

Which is more accurate, average end area or prismoidal?

The prismoidal formula is more accurate and is exact for prismoids. The average end area method usually gives slightly larger volumes when section areas change quickly, but it is simpler and widely used for measurement and payment.

What is the prismoidal correction?

It is the difference between the average end area volume and the prismoidal volume. For a trapezoidal section with side slope s, it can be written as C = L · s · (d₁ − d₂)² / 6, where d₁ and d₂ are the end depths.

How do I calculate cut and fill from survey points?

Import the existing and design (or before and after) survey points, build a TIN for each, define the boundary, and compute the volume between the two surfaces, ideally with a second method such as a grid to verify the result.

What causes wrong cut and fill volumes?

The most common causes are swapped Northing and Easting columns, duplicate points with different elevations, triangles spanning areas without survey data, a wrong boundary, and ignoring bulking and shrinkage factors.

Rawax is a browser-based civil engineering platform that combines survey, roads, architecture, structure, MEP, quantities and project management in one model, with an AI assistant that works in English and Arabic.

Open the Rawax platform